Touch Sensor Calibration Tool
Configure supported detection thresholds.
Tap, click or press Space to keep count.
Tap anywhere inside or press Space
How the Touch Sensor Calibration Tool Works
The Touch Sensor Calibration Tool measures a sensor's untouched baseline and touched readings, then sets the detection threshold between them on supported boards. A well-placed threshold counts real touches and ignores noise.
- Record the baseline: Keep hands away for 5 seconds while the tool samples untouched readings.
- Record touched readings: Touch the pad 10 times as you would in normal use.
- Calculate the threshold: The tool places the threshold between the noise ceiling and the lowest touch reading.
- Write the setting: Send the threshold to boards that accept settings, or copy it into your sketch.
Touch Sensor Calibration Tool Formula
The Touch Sensor Calibration Tool threshold equals the baseline mean plus a share of the gap between the baseline and the average touch reading. The signal-to-noise ratio (SNR) shows how reliable the setting is.
- μ_base
- Mean untouched reading
- σ_base
- Standard deviation of untouched readings (noise)
- μ_touch
- Mean touched reading
- k
- Placement factor, usually 0.4 to 0.6
Example: Baseline mean = 200, noise σ = 4, touched mean = 320. With k = 0.5, threshold = 200 + 0.5 × 120 = 260. SNR = 120 ÷ 4 = 30.
Touch Sensor Calibration Tool Reference Table
The Touch Sensor Calibration Tool conversion table rates sensor setups by signal-to-noise ratio.
| SNR | Rating | Expected behavior | Action |
|---|---|---|---|
| Under 5 | Poor | Frequent false or missed touches | Thinner cover, larger pad, shorter wires |
| 5 to 10 | Marginal | Occasional errors | Raise filtering or pad size |
| 10 to 20 | Good | Reliable in normal conditions | Use as is |
| Over 20 | Excellent | Reliable in noisy conditions | Use as is |
About the Touch Sensor Calibration Tool
A Touch Sensor Calibration Tool is a setup utility that finds the right detection threshold for a capacitive or similar touch sensor.
Sensor readings drift with humidity, temperature and cover material. Chip makers recommend an SNR of at least 5:1, and higher values give a wider safety margin between noise and a real touch.
Ways to Use the Touch Sensor Calibration Tool
There are 5 main uses of the Touch Sensor Calibration Tool, including first-time setup and cover changes.
- First-time setup: Makers set thresholds for a new sensor build.
- Cover changes: Engineers recalibrate after adding glass or acrylic.
- Glove use: Teams tune sensors for gloved fingers.
- Seasonal drift: Installers recalibrate exhibits in humid or dry seasons.
- Production checks: Factories confirm each unit meets a minimum SNR.